Dairy Barn Fans
A healthy cow produces healthy yield and to keep the cattle healthy; maintaining a pleasant environment of Barn is crucial.
We have solutions to keep the herd – happy and healthy. One of them is our efficiently performing Dairy Barn Ventilation Fans. Made of high quality material these fans are best to maintain the Barn temperature.
Key Features:

Milking used to be a manual task but with increasing herd size, manually milking huge number of cattle is time consuming and inefficient. Milking parlors are designed for optimal cattle and farmer comfort.
As the name suggests, cows stand parallel to each other in this design. So, if the cows are standing side to side, that only leaves one access point for the milker to reach the udder: the rear end! In parallel parlors, milking doesn’t begin until all cows are in their stalls, and they are all released from the parlor at one time. Milking only takes about 10 minutes.
Features:
• Ensures milking more cows in a shorter milking time
• Robust design
• Stress-free animal positioning
• Faster exit option for animals

IBT based BMC are also very useful when there is irregular supply of electricity of severe incidents of load shedding. It enables milk farmers to cool the milk even in the absence of grid electricity while reducing the cost and time required for milk cooling significantly. Another reason to prefer IBT based BMC over Direct expansion-based BMC is the rate difference in electricity in day time and night time.
Features:
• 80% saving in Milk Cooling Cost (Rs.0.20/Ltr)
• 75% Bacterial Load is controlled within first 30 mins by ensuring rapid cooling
• Low System Maintenance Cost
• Non-Polluting, Environment friendly
• Easy Operation, skilled labour not required

A heat recovery unit is an insulated water tank through which pipes carry the refrigerant gas to the refrigerant condenser. Heat released from condenser is usually wasted in the environment. With the help of Heat recovery unit heat from the gas is transferred to the water. This water is used to clean BMC during CIP. This saves on the cost and load of BMC operation which is caused by electric water heater. A heat recovery unit can preheat the water to 65 °C-75 °C, depending on the temperature of the water as it enters the tank and the temperature of gas.
Features:
• Capable to generate 200 Litre Water to 65°C-75°C in one run cycle
• Insulated layer in the body ensures minimal Heat Loss
• Reduces the total Power Consumption up to 20%
• Enhances Profitability of the Dairy
• Modular arrangement can be added on existing BMC’s